0.6/1kV pvc insulated Cable

Share to:

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminum or aluminum alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.

Click buttons below to reach our sales and technical team to get fast quotation and support.

Quantity:

APPLICATION of 0.6/1 kV PVC insulated power cable


RMJT 0.6/1 kV PVC insulated power cable are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, underground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

 

STANDARD of RMJT 0.6/1 kV PVC insulated power cable


IEC 60502-1

 

CONSTRUCTION of RMJT 0.6/1 kV PVC insulated power cable


Conductors: The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminum or aluminum alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.

Insulation: PVC Insulation material and thickness shall be as per IEC 60502-1, PVC material shall be Type A as per IEC 60502-1.


Color Code  


Color Code (1) :

1 Core    : Red or Black

2 Cores   : Red, Black

3 Cores   : Red, Yellow, Blue

4 Cores   : Red, Yellow, Blue, Black

5 Cores   : Red, Yellow, Blue, Black, Green

Above 5 Cores: Black Cores with White numerals


Color Code (2) :

1 Core : Brown or Blue

2 Cores   : Brown, Blue

3 Cores   : Brown, Black, Grey

4 Cores   : Blue, Brown, Black, Grey

5 Cores   : Green/Yellow, Blue, Brown, Black, Grey

Above 5 Cores: Black Cores with White numerals


Other colors can be manufactured upon request.


Assembly/ Inner Covering:


The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material. For halogen free cables, the inner covering and fillers shall also be halogen free compound.


Armor:


Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.


Outer Sheath:


Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1,Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.

Fire Performance of Cable Sheaths: Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

Single core (unarmoured)

Nominal Cross Section

Diameter of Conductor

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter

mm²

mm

mm

mm

mm

1x4

2.3

1

1.4

7.1

1x6

2.8

1

1.4

7.6

1x10

3.6

1

1.4

8.4

1x16

4.5

1

1.4

9.3

1x25

5.6

1.2

1.4

10.8

1x35

6.7

1.2

1.4

11.9

1x50

8

1.4

1.4

13.6

1x70

9.4

1.4

1.4

15.1

1x95

11

1.6

1.5

17.2

1x120

12.4

1.6

1.5

18.7

1x150

13.8

1.8

1.6

20.6

1x185

15.3

2

1.7

22.7

1x240

17.5

2.2

1.8

25.4

1x300

19.5

2.4

1.9

28

1x400

22.6

2.6

2

31.7

1x500

25.2

2.8

2.1

35

1x630

28.3

2.8

2.2

38.3


Two cores(unarmoured)

NominalCross Section

Diameter of Conductor Thickness

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter

mm²

mm

mm

mm

mm

2x1.5

1.4

0.8

1.8

9.6

2x2.5

1.8

0.8

1.8

10.4

2x4

2.3

1

1.8

12.2

2x6

2.8

1

1.8

13.2

2x10

3.6

1

1.8

14.8

2x16

4.5

1

1.8

16.6

2x25

5.6

1.2

1.8

19.6

2x35

6.7

1.2

1.8

21.8

2x50

8

1.4

1.8

25.2

2x70

9.4

1.4

1.9

28.1

2x95

11

1.6

2

32.4

2x120

12.4

1.6

2.1

35.4

2x150

13.8

1.8

2.2

39.2

2x185

15.3

2

2.4

43.3

2x240

17.5

2.2

2.5

48.9

2x300

19.5

2.4

2.7

54

2x400

22.6

2.6

2.9

61.5



Threecores(unarmoured)

Nominal Cross Section

Diameter of Conductor Thickness

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter

mm²

mm

mm

mm

mm

3x1.5

1.4

0.8

1.8

10.1

3x2.5

1.8

0.8

1.8

10.9

3x4

2.3

1

1.8

12.9

3x6

2.8

1

1.8

13.9

3x10

3.6

1

1.8

15.7

3x16

4.5

1

1.8

17.6

3x25

5.6

1.2

1.8

20.8

3x35

6.7

1.2

1.8

23.2

3x50

8

1.4

1.8

26.9

3x70

9.4

1.4

1.9

30.1

3x95

11

1.6

2.1

34.7

3x120

12.4

1.6

2.2

38

3x150

13.8

1.8

2.3

42.1

3x185

15.3

2

2.5

46.5

3x240

17.5

2.2

2.7

52.5

3x300

19.5

2.4

2.8

58

3x400

22.6

2.6

3.1

66.1